THE SITUATION
An asphalt plant in the Midlands was experiencing a persistent breakdown to one of their filler elevators on-site. Over the previous four years, this problem had caused 1300 hours of documented downtime, estimated to have cost the plant around £47 million worth of lost revenue. The cause of the issue was a single bearing that was failing on a weekly basis. HAYLEY DEXIS were contacted to visit site, inspect the bearing and offer a solution that would prevent such costly downtime from recurring.
THE SOLUTION
HAYLEY DEXIS collected the damaged bearing from the plant and sent it for analysis. The analysis clearly showed that the current bearing being used within the filler elevator was suffering in such an aggressive operating environment. Technical advisors from SKF were invited to the plant to review the application, and they recommended their Three-barrier Solution which consists of:
– SKF Taconite seal
– Housing cavity grease (SKF LGGB 2 biodegradable grease)
– Sealed SKF Explorer spherical roller bearing
A quote for the solution from HAYLEY DEXIS was accepted and the new bearing delivered promptly.
THE RESULT
The SKF Three-barrier Solution has now been in-place for five months, with the recurring bearing failures now seemingly eradicated. With the downtime costs calculated to be around £11.7 million per year, the solution is on course to make an incredibly valuable difference for the customer by improving uptime and reducing maintenance burden. Around 104 annual hours of engineers’ time previously spent on removing and replacing the failed bearing are now able to be spent on preventative maintenance projects at the plant.